The ECBS002 series photoelectric direct-reading remote water meter is designed to measure and record the total volume of potable water flowing through municipal water pipelines. The measured consumption is converted into digital signals and transmitted for remote data collection.
Using handheld data collectors or existing communication networks, the system enables remote meter reading, monitoring, and management, improving the efficiency and accuracy of water usage management.
• Dry-dial structure design.
• Clear and easy-to-read dial with long-term readability.
• Photoelectric encoded passive direct-reading technology.
• Data output via RS485 bus or M-BUS bus.
• Non-contact sensing technology that does not affect meter performance.
• Low-power design, requiring power supply only during data reading.
• Can be integrated with a host management system to realize remote meter reading and monitoring.
• High measurement accuracy, up to R200.
• Optional valve control function, allowing terminals to open or close the valve to control water usage.
| Permissible Measurement Error: | Q1–Q2: ±5% Q2–Q4: ±2% |
| Communication Interface: | M-BUS / RS485 |
| Communication Protocol: | CJ/T 188-2004 (Data Transmission Specification for Household Metering Instruments) DL/T 645-1997 Modbus Communication Protocol Other protocols available upon agreement |
| Wireless Interface: | Not available |
| Water Temperature (Cold Water): | 0–30 °C |
| Water Temperature (Hot Water): | 0–90 °C |
| Maximum Operating Pressure: | ≤ 1 MPa |
| Nominal Pipe Diameter: | DN15–DN40 |
| Communication Baud Rate: | 1200 / 2400 / 4800 / 9600 bps |
| Maximum Communication Distance: | ≤ 300 m |
| Operating Current: | M-BUS bus: 1.0–1.3 mA RS485 bus: 0.6–0.8 mA |
| Operating Voltage: | M-BUS bus: DC 36 V RS485 bus: DC 12–24 V |
| Minimum Data Retention Time: | Unlimited |
| Electromechanical Conversion Error: | ≤ ±1 minimum conversion scale value |
| Valve Control Function: | Supported |
| Wiring Method: | M-BUS bus: connected using a standard two-core cable, polarity-free. RS485 bus: connected using a standard four-core cable, with two cores for power supply and two cores for signal transmission. |
| Recommended Cable Type: | M-BUS bus: RVSP 2 × 1.0 mm² shielded twisted pair cable RS485 bus: RVSP 4 × 1.0 mm² shielded twisted pair cable |
| Installation Guidelines: | • Install the meter horizontally (vertical meters must be installed vertically), with the dial facing upward and the arrow aligned with the direction of water flow. • Flush the pipeline before installation to remove debris and impurities. • Install the meter in a dry location with convenient access for inspection, maintenance, and replacement. • Installation inside a dedicated water meter box is recommended. • Install isolation valves upstream and downstream of the meter to facilitate maintenance and system control. |